co gas sensor cross reference

ALTAIR® 5X Multigas Detector

XCell Carbon Monoxide (CO) Sensor Gas Applied Approximate % Cross-sensitivity CO 100% NO 84% SO 2-4% HCN -5% Isopropanol -8% H2 48% XCell Ammonia (NH 3) Sensor Gas Applied Approximate % Cross-sensitivity NH 3 100% H2S 75% NO 2-50% SO 2 40% XCell Sulfur Dioxide (SO 2 ) Sensor Gas Applied Approximate % Cross-sensitivity SO 2 100% XCell Chlorine (Cl2) Sensor Gas Applied Approximate % Cross ...

Get Price

Chat With WhatsApp

AUTOFLAME SENSORS GUIDE

• Differential pressure port: used as a reference to measure atmospheric pressurethe , therefore it should always be exposed to atmospheric pressure. Gas / Air Pressure Sensor’s Selection ; When selecting a gas pressure sensor for a specific application, it is necessary that the sensor’s measuring range should be the closest to the gas pressure range of the application. For example; a ...

Get Price

Chat With WhatsApp

Handheld Multi-Gas Detectors Application Note

MOS toxic gas sensors, potentially hindering their ability to detect the presence of a toxic gas. While many toxic gas sensors are quite specific, cross sensitivity does occur. Cross sensitivity is a sensor’s reaction to an interfering gas. Exposing a sensor to a gas that is not the target gas can cause an unwanted response, either

Get Price

Chat With WhatsApp

Gas sensor cross sensitivity - Blackline Safety

Cross sensitivity is a phenomenon that occurs when a sensor shows readings for a gas that is not the target gas. This interfering gas causes a reaction in the sensor — therefore showing a change in readings — even if the target gas is not present. An example of this would be an H₂S sensor …

Get Price

Chat With WhatsApp

Cross references - Gas Tables - Gas Detection /

Cross references Electrochemical sensors are manufactured as specific sensors for one gas, for all that there exist some cross sensitivities to other gases. Generally these cross references are not a problem in gas detection in the area of safety, but they can be a complication in the process detection - they can cause false alarms.

Get Price

Chat With WhatsApp

White-Rodgers Heating Season Cross Reference

Model Number Voltage Stages / Opening Characteristic Pipe Size Regulator Setting Natural Gas Adjustment Range (WC) LP Gas Adjustment Range (WC) LP Conversion Kit Included Reducer Bushing Kit Flow Direction Side Taps Inlet / Outlet Pressure Tap Standing Pilot with Line Interrupter HSI / DSI Intermittent / Proven Pilot 36C SERIES STANDING PILOT

Get Price

Chat With WhatsApp

TRADELINE fi Product Cross Reference - On Time Direct

This cross reference lists both direct and functional replacements. In all cases where a functional replacement is identified, it is the responsibility of the installer to verify that the replacement is suitable for installation. This may require referring to the product specification sheets, contacting the equipment man-ufacturer or other steps to ensure that the safety of the control system ...

Get Price

Chat With WhatsApp

THROTTLE POSITION (TP) SENSORS - Tomco-inc

A complete cross reference from part numbers to Tomco, Inc. part numbers begin on page 357. 299 YEAR ENGINE FOOTNOTE OE # MFG TYPE PART # THROTTLE POSITION SENSORS BUICK 6 CYL. Regal (Cont'd) 2004-1997 (1) 231" 24504798 PFI 14093 1982-1980 (3) 231" 17078448 R-4 CARB 14053 1987-1986 (7) 231" Turbo 25036663 PFI 14063

Get Price

Chat With WhatsApp

Gas Detector Device Cartridges | About Blackline’s G7C & G7X

Blackline’s G7 offers an exclusive modular design with plug-and-play gas sensor cartridges that deliver industry-leading customization for nearly every industry and scenario. G7 offers two gas sensor cartridge options to support gas detection, lone worker monitoring and evacuation management. Clients can select from a broad range of gas sensors, creating a custom configuration for for ...

Get Price

Chat With WhatsApp

Carbon Monoxide Sensor Cross-Sensitivities Alcohols, VOCs ...

Carbon Monoxide Sensor Cross-Sensitivities Alcohols, VOCs & Hydrogen Technical Bulletin Cross-sensitivity to gases other than the target gas of interest is a common sensor characteristic, especially among electrochemical sensors. Cross-sensitivities are limited as much as possible by MSA sensor design and filters; however, some key interactions still occur. CO sensors do have some inherent ...

Get Price

Chat With WhatsApp

Honeywell Fixed Gas Detection Calibration Handbook

sALWAYS use Zero Air calibration gas or reference device (such as a calibrated portable) when doing Zero Calibrations Bump Test A bump test is not intended to be an accurate calibration, but is used as a confidence check to ensure that the gas detection system is functional. Some of the target gases are difficult to handle therefore bump testing often makes use of cross sensitivities so that ...

Get Price

Chat With WhatsApp

Documents - Spec Sensors

Arduino Library for Digital Gas Sensor Modules (DGS) Gas Sensor Datasheets. Carbon Monoxide. IOT_CO_1000-Digital Gas-Sensor-Module 968-028; User Manual IOT-CO-1000; ULSPSM-CO 968-001; 3SP_CO_1000 C Package 110-109; 3SP_CO_1000 P Package 110-102; UL2034 Certificate of Compliance for CO; UL ETL Part Number Package Number Reference; Ozone. ULPSM ...

Get Price

Chat With WhatsApp

Sensors | Cummins Inc.

Cummins Sensors provide a whole solution package, enabling system integration while meeting critical regulations. Cummins provides sensors that support a multitude of critical components on your engine – from controlling the speed of the turbocharger to assisting the level of NOx taken into the aftertreatment system. Product Benefits: Quality Control Cost Effectiveness High System Accuracy ...

Get Price

Chat With WhatsApp

GAS DETECTION Handbook - Gilson Eng

• a summary of key principles in combustible and toxic gas monitoring. • reference data—including physical properties and exposure limits—for the most commonly monitored gases, in industrial and various other environments. • a comparison of the most widely-used gas detection technologies. • a table indicating the gas hazards common to specific applications within major industries.

Get Price

Chat With WhatsApp

Oxygen Sensor Replacement Cross Reference Guide.

In order to identify the sensor that you require, we offer three alternative methods for checking our cross reference databases. 1. Use the search field below and enter the details of the sensor or equipment it is used with. You can search for references to the sensor, equipment or manufacturer. 2. Alternatively, the alphabetical listing can be ...

Get Price

Chat With WhatsApp

Commercial Gas Detection - Honeywell Analytics

PG1100-8-NCL-EN When placing an order, please reference the Order Number (not the Model Number) where applicable. 5 E³Point Toxic & Combustible Gas Monitor E³Point Analog (Single or Dual Gas) Model Number Order Number E³Point without sensor, wall mount, analog, 24 Vac/Vdc E3SA 1309A0042 E³Point without sensor, wall mount, analog, 120 Vac E3SAH 1309A0043

Get Price

Chat With WhatsApp

Why is hydrogen such a big issue for CO sensors? | GfG ...

For instance, carbon monoxide sensors that do not include a filter are sometimes marketed as “dual purpose” sensors for the simultaneous detection of both CO and H2S. This type of sensor responds to both CO and H2S, but cannot tell them apart. The sensor produces a single signal, which is up to the instrument user to interpret. Even though care has been taken to reduce cross-sensitivity in ...

Get Price

Chat With WhatsApp

ALTAIR® 2X, 4X & 5X Gas Detectors

* These cross-sensitivity values are intended for reference only and may change under varying environmental conditions, varying concentrations, varying sensor lots, and varying sensor age. These tables do not contain a complete or inclusive list of cross-sensitive gases, but rather is a sampling of the most common examples. ** All values have been rounded up to the nearest 1 ppm It is quite ...

Get Price

Chat With WhatsApp

TPMS Sensor Cross Reference - Sherco Auto

Sensor Part # Schrader Sensor Schrader Service Pack Kit Color Sensor Manufacturer OE Sensor Part No. Nut Torque (in-lbs.) Nut Torque () 2 Acura 3 Acura CSX 2008-09 TR20204 3 TS28720 TS222720-103 28720 20019 Lt. Blue TRW 42753-SNA-A83 35 4 4 Acura MDX 2004-06 TR20206 4 TS28981 28981 20036 Yellow TRW 42753-S3V-A07 35 4 5 Acura MDX 2007-10 TR20216 1 TSSTK …

Get Price

Chat With WhatsApp

AQ3CO Sensor - Carbon Monoxide (CO) Gas Sensor ...

Compensation Logics of AQ3 Series Sensors Cross Sensitivity Table CHARACTERIZATION NOTE AQ3CO Carbon Monoxide Gas Sensor DOCUMENT PURPOSE The purpose of this document is to provide indicative, technical performance data for the AQ3CO sensor to assist in the integration of the sensor into gas detection instrumentation. The sensor has been subjected to a testing program as …

Get Price

Chat With WhatsApp

Professional gas sensing solution supplier with over 30-year gas sensor manufacturing experience Contact Us